Dimplex Heatbook
Technical information
WARM AIR HEATING
Controllability
Variable input control
Two fan speeds – normal or boost
Day energy switch (Economy 7)
External time clock and
thermostat options
Heating element
Kanthal D iron/aluminium alloy
sheathed in quartz tubes.
Thermal insulation
Basic insulation – microporous silica
and mineral wool.
Air passages and base –
moulded Vermiculite.
Supply
Can be connected to 240v single
phase or 415v three phase supply,
on standard off-peak or Economy 7
(white meter) tariffs.
Every unit is therefore capable of
being wired on site to cover the
following configurations:
Single phase Economy 7
(white meter)
Single phase standard off-peak
Three phase Economy 7
(white meter)
Three phase standard off-peak
Cabinet
0.8mm zinc coated mild steel
finish with polyester/epoxy powder
coated paint.
HB13-D0104
Thermostat
sensing
head
Control
panel
Air
mixing
flap
Return air
through
washable
filter
Plenum
chamber
Air outlet from freestanding unit
Mains cable
entry
Centrifugal
fan
Thermal
core
Core box
insulation
Model R7* R8* R10 R12 R15
Rating 4x1.643kW 5x1.643kW 6x1.643kW 7x1.643kW 9x1.643kW
Active storage capacity 47kWh 55kWh 73kWh 84kWh 104kWh
Case emission 700W 700W 750W 850W 950W
Core weight 385kg 385kg 385kg 457kg 611kg
Assembled weight 482kg 482kg 482kg 600kg 754kg
Dimensions (including/excluding plenum chamber)
Height
1603mm/
1300mm
1603mm/
1300mm
1603mm/
1300mm
1753mm/
1450mm
2053mm/
1750mm
Width 615mm 615mm 615mm 615mm 615mm
Depth 635mm 635mm 635mm 635mm 635mm
Fan performance (m
3
/h)
Normal 625 625 625 710 872
Boost 777 777 777 896 1090
Back pressure (M Bar) 0.15 0.15 0.15 0.15 0.25
Day boost facility
element rating 2x1.643kW 3x1.643kW 4x1.643kW 5x1.643kW 7x1.643kW
*Supplied as Model R10. R7 and R8 achieved by downrating on site.
We recommend this unit is professionally installed by one of our Electricaire installers.
Please see our website for more information.
Air filter
A washable polyester
filter is located in the
detachable filter frame
at the front of the unit.
All live and moving parts
are completely screened
by a fixed mesh when
the filter is removed.
Plenum chamber kit
(PLEN/12)
For all new installations
a plenum chamber kit will
be required at extra cost.
Complete with 3 air register
grilles, this additional
component measures
625mm x 600mm
(including flanges)
with a height of 303mm.
Ducting
In addition to standalone
use, Electricaire can also
be used with ducting
dependent on installation.
89