Setting supplementary electric heater
Index - String
MIN
value
MAX
value
Parameter function
03
This parameter indicates the presence of a supplementary electric heater. Based on the
set value, various solutions can be described:
• set value 0 = No;
• set value 1 = Supplementary heater present but not active during domestic water production;
• set value 2 = Activate resistance command used to authorise activation of outside boiler;
set value 3 = Integration resistance present and active during domestic water production;
Remote panel configuration
Index - String
MIN
value
MAX
value
Parameter function
03
This setting configures the type of control applicable to the units; depending on the value
decided for this setting, the controls on the "functioning mode" (HEAT/COOL) and the unit
"on/off" command will be managed in the following way:
Set value 0:
• Setting functioning mode = set parameter 0
• ON/OFF control = from the panel on the machine
Set value 1:
• Setting functioning mode = set parameter 0
• ON/OFF control = from the remote panel
Set value 2:
• Setting functioning mode = set from remote contact
• ON/OFF control = from the panel on the machine
Set value 3:
• Setting functioning mode = set from remote contact
• ON/OFF control = from the remote contact
Enabling domestic hot water preparation
Index - String
MIN
value
MAX
value
Parameter function
01
In the heat pump models, there is the possibility to produce hot water for domestic use;
this production has it's own changeable setting and it's own band (parameters E, F user
menu); with this parameter you can make parameters E and F visible and usable.
To control the domestic hot water production, once this function has been activated, you
must use the digital input ID6. (Marked on the electric card enclosed with the TWS)
• 1, ENABLE the domestic water function
• 0, DISABLE the domestic water function
The CLOSED status of the clamp means the domestic water function is ACTIVE. This fun-
ction is available from software version 3.7 (the software version is visible as a reading,
with index E). The minimum compressor functioning time, and the defrosting time, take
priority over the production of domestic water.